REMARK: Do not use for construction. Refer to factory certified dimensions & weights. This page includes data current at time of publication, which should be reconfirmed at the time of purchase. In the interest of product improvement, specifications, weights and dimensions are subject to change without notice.

General notes

1. All models are single coil section units. Fan cycling results only in on-off operation. For additional steps of control, the Baltiguard® Drive System and two-speed fan motors are available. More precise capacity control can be obtained with modulating fan discharge dampers.
2. Make up, overflow, suction, drain connections and access door can be provided on side opposite of that shown; consult your BAC representative.
3. Unit height is indicative, for precise value refer to certified print.
4. Shipping/operating weights indicated are for units without accessories such as sound attenuators, discharge hoods, etc. Consult factory certified prints to obtain weight additons and the heaviest section to be lifted.
5. For indoor applications of evaporative condensers, the room may be used a a plenum with ductwork attached to the discharge only. If inlet ductwork is required, an enclosed fan section must be specified; consult your BAC representative for details.
6. Fan kW is at 0 Pa ESP. To operate against external static pressure up to 125 Pa, increase each fan motor one size.
7. Refrigerant charge listed is R 717 operating charge. To determine operating charge of R22 refrigerants, multiply by: 1,93. For R134A, multiply by: 1,98.
8. Refrigerant connections are standard bevelled for welding.

Last update: 21/12/2024

VCL 042H-159M

VCL_042H_159M

1. Refrigerant in ND100; 2. Refrigerant out ND100; 3. Make up ND25; 4. Overflow ND50 on VCL 042-119 & 133 - ND80 on VCL 131 & 140-159; 5. Drain ND50; 6. Access; 7. Spray pump; 8. Fan motor.

Model Weights (kg) Dimensions (mm) Air Flow (m³/s) Fan Motor (kW) Water Flow (l/s) Fluid Outlet ND (mm) R717 charge (kg)
Oper. Weight (kg) Ship. Weight(kg) Heaviest Section (kg) L1L2 W H
VCL 042-H 1610 1100 1100 3350 1820 1250 1585 7.9 (1x) 4.0 5.9 (1x) 0.55 20.0
VCL 048-G 1800 1270 1270 3350 1820 1250 1855 6.7 (1x) 2.2 5.9 (1x) 0.55 28.0
VCL 054-H 1810 1280 1280 3350 1820 1250 1855 7.6 (1x) 4.0 5.9 (1x) 0.55 28.0
VCL 058-G 1990 1440 1440 3350 1820 1250 2015 6.4 (1x) 2.2 5.9 (1x) 0.55 38.0
VCL 065-H 2005 1460 1460 3350 1820 1250 2015 7.4 (1x) 4.0 5.9 (1x) 0.55 38.0
VCL 071-J 2025 1490 1490 3350 1820 1250 2015 8.1 (1x) 5.5 5.9 (1x) 0.55 38.0
VCL 073-H 2190 1640 1640 3350 1820 1250 2230 7.2 (1x) 4.0 5.9 (1x) 0.55 46.0
VCL 079-J 2220 1670 1670 3350 1820 1250 2230 7.9 (1x) 5.5 5.9 (1x) 0.55 46.0
VCL 084-K 2530 1750 1750 4560 2730 1250 1855 11.4 (1x) 7.5 9.0 (1x) 0.75 42.0
VCL 096-J 2810 2010 2010 4560 2730 1250 2090 10.2 (1x) 5.5 9.0 (1x) 0.75 55.0
VCL 102-K 2820 2020 2020 4560 2730 1250 2090 11.2 (1x) 7.5 9.0 (1x) 0.75 55.0
VCL 111-L 2840 2080 2080 4560 2730 1250 2090 12.3 (1x) 11.0 9.0 (1x) 0.75 55.0
VCL 119-M 2845 2090 2090 4560 2730 1250 2090 12.4 (1x) 15.0 9.0 (1x) 0.75 55.0
VCL 115-K 3090 2280 2280 4560 2730 1250 2350 10.8 (1x) 7.5 9.0 (1x) 0.75 72.0
VCL 133-M 3120 2350 2350 4560 2730 1250 2350 13.0 (1x) 15.0 9.0 (1x) 0.75 72.0
VCL 131-L 3560 2490 2490 5480 3650 1250 2090 13.6 (1x) 11.0 12.1 (1x) 1.1 74.0
VCL 140-M 3570 2500 2500 5480 3650 1250 2090 14.8 (1x) 15.0 12.1 (1x) 1.1 74.0
VCL 148-L 3930 2830 2830 5480 3650 1250 2350 13.4 (1x) 11.0 12.1 (1x) 1.1 92.0
VCL 159-M 3940 2840 2840 5480 3650 1250 2350 14.6 (1x) 15.0 12.1 (1x) 1.1 92.0